Eddie, OK here we go again with the spec talk. I get it, I have an expensive 
fridge and I sure do not want to burn it up after all the work winching it out 
of the camper. Are you saying it is a 3 way? three way meaning it also works 
off of 12VDC on its own? whatever it is I assume I should continue to run the 
10G wire but to where? the instructions say go straight to the batt with 10 
gauge wire. 


----- Original Message -----
From: Eddie 
Date: Friday, May 16, 2008 7:35
Subject: [SilverStreak] Norcold Fidge
To: sslist@tompatterson.com

> Curt,<BR>> I found the specs. The 641.3 model is the 3-way. It draws 14.8 
> amps dc thus 
> the need for the 10 gauge feed wire. Both use the same 
> architecture, thus 
> the connector. Normal operation of yours draws less than 10 
> milliamps on 120 
> volts ac. The 1.2 dc amp draw is maximum for powering the propane 
> valve and 
> simultaneous electronic igniter. Once lit, the igniter draw is 
> absent and 
> only the propane draw exists. I will try to get the amp draw spec 
> on the 
> propane valve. On my fork lift valves, the operational draw is 300 
> ma, but 
> those are huge valves for very high volume flow. Wire size for 
> those valves 
> is only 18 gauge and that is overkill.
> 
> This is a really nice fridge.
> -Eddie-
> Houston, TX
>