Dr. J. -- How does one identify the first receptacle in the circuit? My ' 68
Tradewind has three 110VAC breakers in the electrical box. One circuit (20
amp) is for the air conditioner. I assume the other two (15 amp) are for the
receptacles. Sounds like I will need two GFCIs -- one in each circuit so I
have two first receptacles to find.

Thanks,

Jim Greene
' 68 Tradewind

----- Original Message -----
From: "Dr. Gerald N. Johnson, electrical engineer" <geraldj@isunet.net>
To: "Multiple recipients of VACList" <VACList@airstream.net>
Sent: Tuesday, September 25, 2001 3:34
Subject: [VAC] Re: GFCI


> Just ONE GFI per circuit. At the first receptacle. After that the GFI in
> the receptacle protects the rest of the ordinary receptacles (when wired
> correctly according to the instructions with the GFI).
>
> Gerald J.